FIXED GAS DETECTION

With the acquisition of Detcon, Oldham, Simtronics and GMI,
Teledyne has become one of the largest manufacturers of products for
gas and flame detection. These global brands bring together
over 100 years of experience in the sector through a vast
range of innovative solutions for detection.

Comhas as a Teledyne Partner, distributes, configures, provides field assistance and performs start-ups on the entire range of Teledyne gas sensors. Comhas technicians are equipped with the necessary equipment, training and authorizations to be able to intervene in the field.

Also in the gas detection field, Comhas is a distributor for Dalemans, a European company that designs and manufactures innovative gas detection solutions for use in buildings, car parks, laboratories and industrial environments.
We offer complete systems that include design, manufacturing, installation and maintenance of gas detection safety solutions.


โ€ข up to two OLC10s per channel
โ€ข up to five OLC10s per channel
โ€ข Wheatstone bridge output or 4-20 mA (OLCT 10)

The OLC 10 and OLCT 10 are designed for the detection of combustible or toxic gases in tertiary applications (boiler plants, battery charging rooms, car parks, hospitals).

Two 10-s OLCs can be connected to one detection channel to monitor the same area, without additional junction boxes or wiring. Similarly, up to five 10-s OLCTs can be connected to one channel to detect CO, NO or NO2 in car parks.


The OLCT 10N is a digital detector compatible with the MX 32 and MX 43 controllers. A maximum of eight OLCT 10Ns can be connected to an MX 32 and thirty-two OLCT 10Ns to an MX 43.

Semi-automatic calibration with standard gas can be performed by one person without opening or adjusting the case.


โ€ข transmitter with 4-20 mA output and optional backlit display
โ€ข optional 2-wire power supply (electrochemical version)

The CTX 300 is designed for the detection of toxic gases or oxygen in non-explosion-hazardous areas in the industrial and tertiary sectors. The CTX 300 is equipped with factory-calibrated sensors, to facilitate maintenance and in particular sensor replacement.

  • Compact, ideal for OEM applications
  • Stainless steel base
  • Atex Certification for Hydrogen
  • Pre-calibrated sensor


โ€ข one-person, non-intrusive calibration
โ€ข pre-set sensors
The OLCT 60 features a local display and allows non-intrusive access to maintenance menus.
The sensor units are constructed from 316L stainless steel for increased resistance to corrosive agents and can be remotely mounted up to 15 metres from the display for detection in hard to reach areas and also allow direct readings.

The OLCT 60 is an extremely versatile detector. Designed for industry, it is suitable for most applications.


Frequency 2,4GHz (EU) / 900MHz (USA)

Low power requirements
Up to 3km range
Robust mesh network topology
Up to 49 devices per network
Flexible input/output options (analog, on/off, Modbus RS485)

 

โ€ข SIL2 certification (LEL and O2)
โ€ข Optional stainless steel version available
โ€ข Version for high temperatures up to 200ยฐC
โ€ข Available with electrochemical, infrared, semiconductor or MEMS sensors

The OLCT 100 industrial gas detectors are economical, reliable, durable and easy to use. The range is available in a Wheatstone bridge version (OLC) or an analogue transmitter version with 4-20 mA output (OLCT). The 100 series is available in explosion-proof and intrinsically safe versions. The OLC 100 and OLCT 100 are SIL2 certified to IEC 61508 and EN 50402 (depending on the gases detected).


โ€ข one-person, non-intrusive calibration
โ€ข standard RS485 output
โ€ข Built-in relays and optional HART communication protocol

The iTrans2 is a highly flexible one or two sensor transmitter with low installation costs. Thanks to its excellent performance, it is suitable for all industrial applications.

Its features include: pre-calibrated sensors, local or remote sensors, non-intrusive calibration, optional stainless steel version, built-in relays, RS485 output for network, high visibility LED display, etc.


โ€ข does not need to be recalibrated on site

โ€ข 5 year warranty
โ€ข SIL2 certification by TรœV-Rheinland
โ€ข standard HART protocol

The GD10P detector is the top of the range infrared detectors.
Equipped with two infrared sources, with multi-beam technology, the GDP10 is so reliable that it requires no maintenance throughout its useful life.

The ultra-fast response time (T90 < 2 s), stainless steel construction, heated optics, 5-year detector and 15-year source warranty, global certification and HART communication protocol make the GD10P one of the most used detectors in the oil and gas industry.


โ€ข one-person, non-intrusive calibration
โ€ข Pre-calibrated sensors
โ€ข Built-in relays
โ€ข optional HART communication protocol

The DG-7 gas detectors are easy to use and maintain and use a wide range of sensors.
The electrochemical sensors are certified intrinsically safe and can be replaced without disconnecting the detector. The DG-7, constructed of stainless steel and equipped with a bright display that changes color according to the status (alarm, fault, normal, preheating), is an industrial detector suitable for harsh environments.


โ€ข specifically designed for harsh environments and extreme conditions

โ€ข waterproof, corrosion and vibration proof
โ€ข one-person, non-intrusive calibration

The 700 series is designed for extreme environmental conditions. The case is made of stainless steel and the electronics are encapsulated in resin to protect them from the external environment.

It also features factory-calibrated โ€œsmartโ€ detection sensors, which are recognized by the detector for easy replacement in the field.


โ€ข Smart sensors that can be replaced while the system is running (hot-swappable)

โ€ข One-person, non-intrusive calibration
โ€ข A single sensing head suitable for all types of sensors
โ€ข Complete range of sensors for combustible and toxic gases

The Meridian is a transmitter that can support one, two or three sensors for maximum flexibility. Thanks to its excellent performance, it is suitable for all industrial applications.

Features include: pre-calibrated intelligent sensors, hot-swappable in ATEX zones, local or remote sensors, non-intrusive calibration, optional stainless steel version, built-in relays, RS485 output for networking, high visibility graphic display and global certifications.


โ€ข up to 256 detectors, 64 logic inputs and 256 relays per system
โ€ข automatic ventilation control

The CPS (Car Park System) gas detection unit uses a fieldbus and can support up to 256 detectors and as many relays connected in a network on 8 different lines. With a speed 1000 times faster than a pump system, the CPS is safer and ensures optimal ventilation management, while reducing energy consumption.

The user-friendly interface consists of a large LCD screen displaying real-time measurements, 3 LED indicators and system status icons (running, forced running, fault, alarm, low speed, high speed, etc.).

Dalemans logo

โ€ข Gas: Toxic, Explosive, Asphyxiating

โ€ข Output signal: CAN-bus

โ€ข Degree of protection: IP65

โ€ข ATEX equipment category: No ATEX

โ€ข Diet: 10 Vdc โ€“ 30 Vdc

โ€ข Minimum operating temperature: โˆ’10 ยฐ C

โ€ข Max. operating temperature: + 40 ยฐ C

Dalemans logo

โ€ข Gas category: Explosives
โ€ข Measuring range: 0 โ†’ 100% LEL
โ€ข Output signal: Analog voltage
โ€ข Degree of protection: IP65K
โ€ข ATEX equipment category: 3G
โ€ข Compatible ATEX zones: 2 Zone
โ€ข Diet: 10 Vdc โ€“ 30 Vdc
โ€ข Minimum operating temperature: 0 ยฐ C
โ€ข Maximum operating temperature: + 50 ยฐ C

Dalemans logo

โ€ข Gas category: Toxic, asphyxiating
โ€ข Measuring range: 0 โ†’ 100% LEL
โ€ข Output signal: 4โ€“20 mA
โ€ข Degree of protection: IP65K
โ€ข ATEX equipment category: No ATEX
โ€ข Diet: 10 Vdc โ€“ 30 Vdc
โ€ข Minimum operating temperature: โˆ’20 ยฐ C
โ€ข Max. operating temperature: + 40 ยฐ C

Dalemans logo

โ€ข Gas category: Explosives
โ€ข Measuring range: 0 โ†’ 100% LEL
โ€ข Output signal: 4โ€“20 mA
โ€ข Degree of protection: IP65K
โ€ข ATEX equipment category: 3G
โ€ข Compatible ATEX zones: 2 Zone
โ€ข Diet: 10 Vdc โ€“ 30 Vdc
โ€ข Minimum operating temperature: 0 ยฐ C
โ€ข Max. operating temperature: + 50 ยฐ C

Facebook
LinkedIn
Instagram