MASS FLOW METER AND REGULATORS

Alicat Mass Flow Meters and Regulators

I mass flow meter e Alicat regulators Mass flow meters are indispensable precision instruments for measuring and controlling gas flow in numerous industrial and laboratory applications. Unlike traditional volumetric meters, mass flow meters They directly measure the mass of the gas passing through the sensor, ensuring accuracy, stability and independence from temperature and pressure variations.

Comhas offers a complete range of mass flow meter e mass flow controller of the best international manufacturers, including Alicat Scientific, a world-leading brand in the sector.
As an official Alicat Scientific distributor, Comhas offers flow measurement and control instruments characterized by high precision, fast response times and wide compatibility with technical, specialty and custom gas mixtures.

READ MORE

The instruments Alicat They stand out for their advanced differential pressure technology.

Up to 130 different gases can be selected directly from the display or via digital interface. Versions with analog and digital outputs (RS-232, Modbus, Profibus, EtherCAT) and NIST-certified calibration options are available, ideal for industrial, scientific, and research applications.

Main features and benefits

  • Direct mass flow measurement
  • High rangeability
  • Fast response times (<10 ms) and long-term stability
  • Single or multi-gas versions with menu selection
  • Integrated regulators (Mass Flow Controller) for automatic flow control
  • Wide choice of interfaces and communication protocols
  • Traceable certifications and calibrations according to international standards

Typical applications

I Alicat mass flow meters and regulators they are used in:

  • Gas production and mixing plants
  • Environmental research and testing laboratories
  • Process analysis and instrumentation systems
  • Pharmaceutical, food and biomedical applications
  • Control of automated industrial processes

I would choose Alicat mass flow meters and regulators Distributing by Comhas means relying on reliable, precise, and certified instruments, supported by a specialized technical team and the many years of experience of an official Alicat Scientific distributor.

alicat_logo

  • Full scale flow range from 100 SCCM to 20 LPM
  • The smallest controller of Alicat mass flow rate
  • Control accurate of the flow rate in a metal body compact e resistant

alicat_logo

  • Custom valve sizing maximizes performance for H2
  • Easy monitoring
  • Fast and constant control

alicat_logo

  • Available ranges: max 0-5000 slpm, min 0-0.5 sccm/0-500 sฮผlm
  • Adjustment range: 0.01% โ€“ 100% FS
  • Accuracy Standard, NIST traceable: +/- (0.6% VL on most models)
  • Optional high precision calibration, NIST traceable: +/- (0.5% VL on most models)
  • Repeatability: +/- 0.1% VL + 0.02% FS
  • Regulation response time (typical): 50-100 ms (up to 25 ms with PID tuning)
  • No preheating time required

alicat_logo

  • Available ranges: max 0-5000 slpm, min 0-0.5 sccm/0-500 sฮผlm
  • Rangeability: 0.01% โ€“ 100% FS
  • Accuracy Standard, NIST traceable: +/- (0.6% VL on most models)
  • Optional high precision calibration, NIST traceable: +/- (0.5% VL on most models)
  • Repeatability: +/- 0.2% FS
  • Response time (typical): 5-10 ms
  • No preheating time required

alicat_logo

  • Available ranges: max 0-5000 slpm, min 0-0.5 sccm/0-500 sฮผlm
  • Rangeability: 0.01% โ€“ 100% FS
  • Accuracy Standard, NIST traceable: +/- (0.6% VL on most models)
  • Optional high precision calibration, NIST traceable: +/- (0.5% VL on most models)
  • Repeatability: +/- 0.2% FS
  • Typical response time (measurement): 5-10 ms
  • No preheating time required

alicat_logo

  • Available fields:
    โ€“ 3 meters of your choice with a range up to 500 slpm (PCU and PCUS) or 250 slpm (PCUW)
    โ€“ All meters also include the Totalizer option
  • Rangeability: up to 1,000,000:1 (sum of 3 instruments)
  • High accuracy traceable to NIST (standard on PCU): +/- (0.6% VL) for intermediate flow rates
  • Repeatability: 0.2% FS
  • Typical response time (measured): 5-10 ms
  • No preheating required

alicat_logo

โ€“ I specify

โ€“ High rangeability

โ€“ Digital and analog communication

-Available with Ethernet/IP, EtherCAT, DeviceNet, Profibus or Modbus (RTU and TCP/IP) communication

alicat_logo

  • Measurement of aggressive fluids (gases)
  • Flow rate up to 5000 SLPM
  • Standard accuracy: +/- 0,8% VL + 0,2% fs
  • High response speed (5-10ms typical)
  • No warm up required
  • High rangeability

alicat_logo

  • Available ranges: max 0-1000 slpm, min 0-0.5 sccm/0-500 sฮผlm
  • Rangeability: 0.01% โ€“ 100% FS
  • Standard Accuracy, NIST Traceable: +/- (0.8% VL + 0,2% FS )
  • Optional high precision calibration, NIST traceable: +/- (0.4% VL + 0,2% FS)
  • Repeatability: +/- 0.2% FS
  • Response time (typical): 5-10 ms
  • No preheating time required

alicat_logo

  • Available ranges: max 0-5000 slpm, min 0-10 sccm
  • Adjustment range: 0.01% โ€“ 100% FS
  • Accuracy Standard, NIST traceable: +/- (0.6% VL on most models)
  • Optional high precision calibration, NIST traceable: +/- (0.5% VL on most models)
  • Repeatability: +/- 0.1% VL + 0.02% FS
  • Regulation response time (typical): 50-100 ms (up to 25 ms with PID tuning)
  • No preheating time required

alicat_logo

  • Available fields : max 0-20 slpm, min 0-0.5 sccm/0-500 sฮผlm
  • Adjustment range: 0.01% โ€“ 100% FS
  • Standard Accuracy, NIST Traceable: +/- (0.6% VL on most models)
  • Optional high precision calibration, NIST traceable: +/- (0.5% VL on most models)
  • Repeatability: +/- 0.1% VL + 0.02% FS
  • Response time (typical) : 50-100 ms (up to 25 ms with PID tuning)
  • Valve pneumatic leak integrity (MCV only): 1 x 10-9 atm scc/sec max with Helium
  • No preheating time required

alicat_logo

  • Measuring ranges: -5000 to +5000 slpm, min -0.5 to +0.5 sccm/-500 sฮผlm to +500 sฮผlm
  • Adjustment range: 0.01% โ€“ 100% FS
  • Accuracy Standard, NIST traceable: +/- (0.6% VL on most models)
  • Optional high precision calibration, NIST traceable: +/- (0.5% VL on most models)
  • Repeatability: +/- 0.1% VL + 0.02% FS
  • Response time (typical): 50-100 ms (up to 25 ms with PID tuning)
  • No preheating time required

alicat_logo

  • Measuring ranges: max 0-5000 slpm, min 0-0.5 sccm/0-500 sฮผlm
  • Adjustment range: 0.01% โ€“ 100% FS
  • Standard Accuracy, NIST Traceable: +/- (0.8% VL +0,2% FS)
  • Optional high precision calibration, NIST traceable: +/- (0.4% VL + 0,2% FS)
  • Repeatability: +/- 0.2% FS
  • Response time (typical) in regulation: 0.5 SCCMโ€“5 SCCM: 100โ€“4000 ms 10 SCCMโ€“20 SLPM: 30โ€“4000 ms 50 SLPMโ€“5000 SLPM: 30โ€“150 ms
  • No preheating time required

alicat_logo

  • Available ranges: max 0-1000 slpm, min 0-0.5 sccm/0-500 sฮผlm
  • Adjustment range: 0.01% โ€“ 100% FS
  • Standard Accuracy, NIST Traceable: +/- (0.8% VL + 0,2% FS )
  • Optional high precision calibration, NIST traceable: +/- (0.4% VL + 0,2% FS)
  • Repeatability: +/- 0.2% FS
  • Regulation response time (typical): 50-100 ms (up to 25 ms with PID tuning)
  • No preheating time required

alicat_logo

  • Long-term stability due to extremely low zero drift.
  • Resistance to process water contamination.
  • ASME Compliant Materials. 316L Stainless Steel and FDA Class VI USP Certified Elastomers
  • Integrated display for local process monitoring.
  • Optional IP66 protection


โ€ข Compressor balancing, and consumption
โ€ข Check for leaks
โ€ข Portable measurement for quick verification of individual utilities
โ€ข Gas process measurements
โ€ข Nitrogen generator measurements

ATEX_WEB_COMHAS

โ€ข Robust, with IP 67 die-cast aluminum housing
โ€ข Wetted parts in stainless steel 1.4571
โ€ข Versions from 1/2โ€ณ up to 2โ€ณ
โ€ข Upon request in ATEX II2 G Ex d IIC T4 execution
โ€ข On request with DVGW approval for natural gas
โ€ข Max pressure 50 bar โ€“ optional up to 100 bar
โ€ข Temperature range up to 180ยฐ C, optional up to 350ยฐ C
โ€ข No moving parts
โ€ข Robust sensors, easy to clean
โ€ข Rotatable case, 180ยฐ rotatable display
โ€ข Scale engraved on the probe for accurate insertion during


โ€ข Mass flow meters for air or gas in-line or insertion versions
โ€ข Atex and IECEX executions

Comhas Srl Via Matteotti, 66 20092 โ€“ Cinisello Balsamo, Milan T: +39 02/6129.8551 โ€“ F: +390266594921 - P.IVA07953790156 - REA 1190884 - Cap. Soc. โ‚ฌ 56.100 โ‚ฌ - privacy policy - cookie policy
Facebook
LinkedIn
Instagram