AT2-3000MR/MRS – Explosion-proof ATEX/IECEx Exd Photohelic® pressure switch/gages

Quick Overview

ATEX_WEB_COMHAS     logo_iecex

• Atex/IECEX Exd Photohelic® pressure switch/gage now available from Comhas as single instrument Atex approuved
• 3 in 1, indicating gage, lo-limit and hi-limit control
• Repeatability ±2%

Description

Atex:
CE 1370
Ex II 2G Ex d IIC T6 Gb
II 2D Ex tb IIIC T85°C Db, -60°C≤T amb≤+60°C
Certificate: BVI 14 ATEX 0072

IECEx:
Ex d IIC T6 Gb
Ex tb IIIC T85°C Db
Certificate: IECEx EPS 14.0082

Esecuzione:
IP66 (IP65 with option OPV)

Photohelic® switch/gages series AT3-A3000 function as versatile, highly repeatable pressure switches combined with a precise pressure gage employing the time-proven Magnehelic® gage design. The Photohelic® switch/gage measures and controls positive, negative or differential pressures of air and compatible gases. Standard models are rated to 25 psig (1.7 bar) with options to 35 (2.4) or 80 (5.5 bar) psig. Single pressure 36000S models measure also available. Two phototransistor actuated, DPDT relays are included for low/high limit control. easy to adjust setpoint indicators are controlled by knobs located on the gage face (accessible opening case after de-enegizing instrument).
Individual setpoint deadband is one pointer width – less than 1% of full scale. Setpoints can be interlocked to provide variable deadband – ideal for control of fans, dampers, etc. Gage reading is continuous and unaffected by switch operation, even during loss of electrical power.
Several ranges available (see standard ranges table).

AT2-3000MR/MRS specifications

Service: air and compatible clean and dry gases.
Wetted parts: consult factory.
Temperature limits*:
Photohelic®: from -6.67 a 48.9°C (20 to 120°F). Option “LT” low temperature to -20°F (-28.8°C) see also case temperature limits.
Case: from -60 to 60°C (see also above, Photohelic® temperature limits).
Accuracy: ±2% f.s. at 70°F (21.1°C); ±3% on -0; ±4% on -00 models
Pressure limits: -20” Hg to 25 psig (-0.677 bar to 1.72 bar).
MP option; 35 psig (2.41 bar)
HP option; 80 psig (5.52 bar).
A36003S – A36010S; 150 psig (10.34 bar).
Dial size: 4” (101.6 mm).
Mounting orientation: diaphragm in vertical position.
Housing material: alluminium (optional stainless steel).
Finishing: texture epoxy coat RAL7038 (only aluminium housings).
Process connections: 1/8” female NPT brass (stainless steel optional).
In case of acetylene presence it is compulsory to use stainless steel.
Electrical wiring: screw terminals.
Electrical connection: 3 x 1/2” NPT F standard (supplied without cable gland).
Set point adjustment: adjustable knobs on face of Photohelic® available behind cover
(follow instructions and ­safety warnings to open cover).
Dimensions: see drawing below.
Weight: 12,9 Kg ab.
Response time**: from f.s. to 0 up to 120 sec. max
(mainly for low ranges models 60, 100 e 125 Pa or equivalentes).

SWITCH SPECIFICATIONS

Switch Type: each setpoint has 1 form C relay (SPDT).
Repeatability: ±1% of full scale.
Electrical rating: 10A @ 28 Vcc; 10A @ 120, 240 Vca.
Power requirements: 120 VAC, 50/60 Hz;

* The operating ambient temperature it is always defined by the limits of measuring elements or options selected.
** For applications with high cycle rate within gage total pressure rating, next higher rating is recommended. See medium and high options.

CAUTION FOR USE ONLY WITH AIR OR COMPATIBLE GASES!
CONTACT FACTORY FOR USE WITH GASES, OTHER THAN AIR AND NITROGEN.

Top