PORTABLE INSTRUMENTS โ TEMPERATURE / HUMIDITY
![]()
- Precision: Instrument ยฑ0,1 % v.MW. ยฑ1 ยฐC; Reference junction ยฑ0,3 ยฐC
- Measurement speed: About 3 measurements per second
- Supply: 2 x AAA batteries (included)
![]()
- Protection class: IP65 / 67 (only with waterproof probes connected to devices with BNC connection)
- Precision: โ 20 โฆ +100 ยฐC: ยฑ0,1 K ยฑ1 digit
โ 70 โฆ +250 ยฐC: ยฑ0,2% of the measured value ยฑ2 digits - Entrance: fixed Pt1000 probe
- Supply: 2 AA alkaline batteries (included)
![]()
- Protection class: IP 67 (except connection to the probe), IK 04
- Storage capacity: PRO 135.2 only: Up to 1 million data sets, file system-based.
Each dataset includes date/time and measurement. The data is stored in CVS files. - Registration type: only PRO 135.2: Automatic with manual start/stop
- Precision: ยฑ(0,2 ยฐC + 0,2% of measured value) ยฑ 1 digit (J, K, N, T, E)
ยฑ(0,5 ยฐC + 0,4% of measured value) ยฑ 1 digit (S, B, R)
![]()
- Class of protection: IP 67 (except connection to the probe), IK 04
- Storage capacity: PRO 115 only: Up to 1 million data sets, file system-based.
Each dataset includes date/time and measurement.
The data is stored in CVS files. - Precision: resolution 0,01: ยฑ(0,03 ยฐC + 0,06% of measured value) ยฑ 1 digit;
resolution 0,1: ยฑ(0,1 ยฐC + 0,2% of measured value) ยฑ 1 digit.
![]()
- Precision: ยฑ0,5% of the reading value ยฑ1 ยฐC
- Supply: 2 AA alkaline batteries (included)
- Energy consumption: <1mA
![]()
- Precision: Instrument ยฑ0,1 % v.MW. ยฑ1 ยฐC; Reference junction ยฑ0,3 ยฐC
- Measurement speed: About 3 measurements per second
- Supply: 2 x AAA batteries (included)
![]()
- Precision: โ 20 โฆ +100 ยฐC: ยฑ0,1 K ยฑ1 Digit
โ 70 โฆ +250 ยฐC: ยฑ0,2% of the measured value ยฑ2 Digit - Supply: 2 AA batteries
- Energy consumption: approximately 5000 hours of operation
![]()
- Class of protection: IP65 / 67 (only with waterproof probes connected to devices with BNC connection)
- Precision: โ 20 โฆ +100 ยฐC: ยฑ0,1 K ยฑ1 Digit
โ 70 โฆ +250 ยฐC: ยฑ0,2% of the measured value ยฑ2 Digit - Entrance: fixed Pt1000 probe
![]()
- Class of protection: IP54
- Precision: -20 .. +100 ยฐC: ยฑ 0,1 K ยฑ 1 Digit
other: ยฑ 0,2 % of measured value ยฑ 2 Digit - Measuring range: Temperature -70,0 โฆ +250,0 ยฐC (-94,0 โฆ +482,0 ยฐF)
- Sensor: Pt1000
![]()
- Precision: โ 20 โฆ +100 ยฐC: ยฑ0,1 K ยฑ1 Digit otherwise 0,1% of the read value
ยฑ2 Digit, more sensor inaccuracy - Supply: 2 AA batteries
- Energy consumption: approximately 5000 hours of operation
![]()
- Precision: at 37ยฐC better than ยฑ 0,05ยฐC
- Supply: 2 x AAA batteries (included)
- Energy consumption: >2500 h (without backlight, with backlight >1000 h);
4-level battery status indicator;
Automatic shutdown, adjustable
![]()
- Precision: โ 20 โฆ +100 ยฐC: ยฑ0,1 K ยฑ1 digit
โ 70 โฆ +250 ยฐC: ยฑ0,2% of measured value ยฑ2 digits - Supply: 2 AA batteries
- Energy consumption: approximately 5000 hours of operation
![]()
โข Precise dew point measurement down to dew point values โโof -80ยฐ Ctd
โข Fast response time
โข 3.5โ 3.5โณ touch screen graphic display
โข Integrated data logger function
โข USB interface for transferring stored data via USB stick
โข Calculates all necessary humidity parameters such as: g/mยณ, mg/mยณ, ppm V/V, g/kg, ยฐCtdatm (languages โโselectable from menu)